----------------------------------------------------------------------
【Voltage Compatibility】
When using electrical appliances, please note that they are designed for Japanese voltage specifications (90-110V), so if you use them with a different voltage, it may cause a malfunction.
【Plug Type】
Our products use Japanese plug types (A or B type).
Please use a conversion adapter if necessary.
【Important Note on Transformers and Adapters】
A transformer adjusts voltage to match your device’s requirements.
A conversion adapter only changes the plug shape and does not adjust voltage.
Using only a conversion adapter without a transformer may result in damage to the product.
【Liability】
We are not responsible for malfunctions or damages caused by improper use, such as operating the product without a transformer.
----------------------------------------------------------------------
Measurement range: 0-25mm; Minimum reading: 0.001mm; Accuracy: ±0.003mm
Micrometer material: carbide probe, durable
:1*CR2032 Lithium
The large, clear LCD display and digital display are easy to read. It will automatically turn off after 5 minutes of inactivity.
The digital micrometer can measure both absolute and relative values. Operating temperature: 0-40°C. Operating humidity: ≤80%.
1: ON/OFF...SET: Turn the power on or off by pressing and holding this button, then briefly pressing the SET button. 2: Press the ZERO button to reset the data to the default value. 3: ABS...in/mm: Relative and absolute measurement conversion keys, metric and inch conversion keys. Briefly press this button to convert absolute and relative measurements. Long press this button to convert between millimeters and inches. How to Use: (1) Before using this product, rotate the dedicated battery cover key counterclockwise to the center of the battery cover, open the battery cover, replace the battery, then rotate the battery cover clockwise to check that the LCD display is normal. (2) Turn the locking wrench, wipe the spindle with a clean cloth, and rotate the high-speed moving axis to separate the two probes at a certain distance and wipe the measuring surfaces. (3) Bring the two probes close together, rotate the ratchet sleeve, bring the two measuring surfaces together, and check that the data is 0. If measurement has started, start measurement. If it is not zero, press 0 to erase the data and measure.
(4) To ensure accurate measurements, when the load tapping ring rings 3 to 5 times, the ratchet sleeve must be rotated as the gauge surface approaches the workpiece, ensuring that the workpiece surface is completely flat and stopping rotation. Important Notice: ● The digital micrometer is a precision gauge. Do not drop it when using it. Recalibrate it before use. ● Avoid contact with dust during use. ● Do not wash the measuring surface with gasoline or alcohol.