Ethernet Remote IO Data Acquisition Module TCP with LED Indicator Light
Farba
Ako na obrázku







Popis
Feature: 1. Wide working voltage DC9?36V, and has anti?reverse protection function. It adopts industrial?grade 32?bit chip, has perfect anti?lightning and anti?interference measures to ensure reliability. 1 isolated 10/100M adaptive Ethernet interface, with 15KV ESD protection. With LED to indicate the working status, with a reset button to reset, easy to install and debug on site. It adopts metal shell, protection grade is IP30, metal shell and system safety isolated from each other, especially suitable for industrial control field applications. Small size, 82x40x99mm/3.2x1.6x3.9in, support wall installation or DIN35mm industrial rail installation. 2. Optocoupler isolated digital input, support wet contact input (dry contact is not supported), the 1channel can be used for pulse counting, support high?speed pulse and low?speed pulse mode, the default is high?speed pulse frequency up to 700KHz, optional low?speed pulse frequency. The maximum is 10KHz. Support DIN2?DIN12 as a low?speed pulse counter, you can set the anti?jitter time 1?2000ms, the default is 1ms, and the corresponding pulse frequency is up to 1KHz. 3. DO output supports triode sink output, the 1 channel can be used as high?speed pulse output, supporting pulse frequency 10Hz?300KHz. Support isolated 12?bit resolution analog input: 0?5V, 0?10V, 0?20mA, 4? 20mA differential input. 1 RS485 communication interface, support standard RTU protocol for expansion. Support 8 channel digital input (DIN), 8 channel digital output (DO), 8 channel analog input (AIN). 1 channel DC power is output to other devices on site, reducing the difficulty and cost of on?site wiring. It can be managed and configured through the LAN connection configuration software, which is easy to operate and maintain. 4. Designed in accordance with the requirements of harsh industrial application environments, it is widely used in various industrial automated production, security monitoring systems, automated measurement and control systems. Users can use different I/O modules and expand the function RTU, flexibly combine them into different I/O combination requirements, and provide users with a complete solution. 5. It can be used for intelligent agricultural temperature and humidity data collection and monitoring, intelligent breeding temperature and humidity data collection and monitoring, storage and library temperature and humidity data collection and monitoring, weather station information data collection and monitoring, cold storage, fruit and vegetable storage rooms, Temperature monitoring of industrial computer rooms, transformer cabinets, and other occasions where monitoring points are scattered, data transmission of solar monitoring systems, data collection and transmission of charging piles, data transmission of ATM, POS, electricity meters, PLC, DAQ and other equipment, smart grid data Acquisition control, intelligent traffic data acquisition control, industrial automation data acquisition control, environmental protection data acquisition control. Specification: Item Type: Ethernet Remote IO Data Acquisition Module Material: MetalPower Supply : Input Voltage: Output: 9-36VDC Power Consumption: Typical Standby Power Consumption: less than 2W Power Output: 1 channel Output Voltage: 9-36V DC (equal to the input voltage) Output Current: 1500mA at 12V (maximum) Power Protection: Anti-reverse Connection, ESD Air: 15KV, Surge: 4KV Ethernet: Ethernet Port Specifications: 1 x RJ45, 10M/100Mbps Network Port Protection: ESD Contact: 8KV, Surge: 4KV (10/1000us) Protocol: RTU, TCP, MQTT Serial Port: Number Of Serial Ports: 1 x RS485 Serial Port Baud Rate: 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000 Data Bits: 7, 8 Check Digit: None, Even, Odd Stop Bits: 0.5, 1, 1.5, 2 Protocol: RTU (slave), RTU (master) Serial Port Protection: ESD Contact: 8KV Surge: 4KV (8/20us) Digital Input: Quantity: 8 channels Input Type: Wet contact (dry contact is not supported), wet contact supports both NPN type sensor and PNP type sensor Wet Contact: Closed: 10-30VDC, Open: 0-3VDC Others: Support DIN1 As A Pulse Counter: Support high-speed pulse and low-speed pulse mode, the default is high-speed pulse frequency up to 700KHz, optional low-speed pulse frequency up to 10KHz. Support DIN2-DIN12 As A Low-speed Pulse Counter: You can set the anti-shake time 1-2000ms, the default is 1ms, and the corresponding pulse frequency is 1KHz. Isolation Protection: 2KVrms Sampling Rate: 100Hz Digital Output: Quantity: 8 channels Output Type: SINK Output Capacity: 500mA per contact Overvoltage Protection: 50VDC Pulse Output: The First Channel DO Supports Pulse Output Function, Pulse Output Frequency: 10Hz-300KHz Analog Input: Quantity: 8 channels Input Mode: Differential input Input Type: 4-20mA, 0-20mA, 0-5V, 0-10V Resolution: 12Bit Accuracy: +/-0.1percent FSR at25 celsius , +/-0.3percent FSR at-10 and 60 celsius , +/-0.5percent FSR at-40 and 75 celsius Sampling Rate: 20Hz Input Impedance: Voltage Type: >1M ohms Current Type: 162 ohms Software Parameters: Network Protocol: IPV4, TCP/UDP, DNS, RTU, TCP, MQT Protocol Conversion: Support TCP and RTU protocol conversion Support RTU to MQTT and TCP to MQTT Indicator Light: Power supply, Link, RS485_RXD, RS485_TXD, IO port status User Configuration: PC software configuration, support WIN XP, WIN 7, WIN 8 and WIN 10 Mapping Data Boolean: 300, 16 Bits: 300 Registration Package: Support custom registration package How to Use: 1. Connect with routers, switches, HUBs and other interconnection switching equipment through straight-through cables, or connect with PC computers and other terminal equipment through crossover cables. And make sure that the device and the computer are in the same local area network. 2. Connect the 9-36VDC power supply to the power terminal of the device, the PWR light is on, and the device will complete the initialization operation in a few seconds. 3. On the PC, open the configuration software, click "Device Search" to find the device, double-click the found device, and enter the password to log in (the default password is 1234). After the password is verified, you can set the parameters.. Package List: 1 x M160T Terminal1 x Rail Mounting Accessories Package1 x Manual Scan Download Card Note: If the first connection is to connect to a PC through a crossover cable, the device IP will be 192.168.1.110, and you need to change the computer IP to 192.168.1.* to find the device.